Leadshine 3 Phase Microstep Drive 3DM580

  • 2,750.00EGP
    • Ex Tax:2,750.00EGP
    • Product Code: Leadshine 3 Phase Drive 3DM580
    • Availability: In Stock
    Leadshine 3 Phase Microstep Drive 3DM580 RS232 2.5A-8A 1-axis Max.500Khz Parameters3DM580MinTypicalMaxUnitOutput Current1.0-8.0ASupply Voltage+1836+50VDCLogic Signal Current71016mAPulse Input Frequency0-500kHzIsolation Resistance100MΩSuitable Stepper MotorsNEMA 23, 34    P1 ..

    Leadshine 3 Phase Microstep Drive 3DM580 RS232 2.5A-8A 1-axis Max.500Khz

     

    Parameters

    3DM580

    Min

    Typical

    Max

    Unit

    Output Current

    1.0

    -

    8.0

    A

    Supply Voltage

    +18

    36

    +50

    VDC

    Logic Signal Current

    7

    10

    16

    mA

    Pulse Input Frequency

    0

    -

    500

    kHz

    Isolation Resistance

    100

    Suitable Stepper Motors

    NEMA 23, 34

     

     

     

     

    P1 Function

    3DM580 Details

    PUL+

    Pulse signal: In single pulse (pulse/direction) mode, this input represents pulse signal, each rising or falling edge active (software configurable);4-5V when PUL-HIGH, 0-0.5V when PUL-LOW. In double pulse mode (pulse/pulse) , this input represents clockwise (CW) pulse,active both at high level and low level (software configurable). For reliable response, pulse width should be longer than 2.5 us. Series connect resistors for current-limiting when +12V or +24V used. The same as DIR and ENA signals.

    PUL-

    DIR+

    DIR signal: In single-pulse mode, this signal has low/high voltage levels, representing two directions of motor rotation; in double-pulse mode (software configurable), this signal is counter-clock (CCW) pulse,active both at high level and low level (software configurable). For reliable motion response, DIR signal should be ahead of PUL signal by 5 us at least. 4-5V when DIR-HIGH, 0-0.5V when DIR-LOW. Please note that rotation direction is also related to motor-driver wiring match. Exchanging the connection of two wires for a coil to the driver will reverse motion direction.

    DIR-

    ENA+

    Enable signal: This signal is used for enabling/disabling the driver. High level (NPN control signal, PNP and Differential control signals are on the contrary, namely Low level for enabling.) for enabling the driver and low level for disabling the driver. Usually left UNCONNECTED (ENABLED).

    ENA-

     

     

     

    P2 Function

    3DM580 Details

    GND

    Power Ground

    +Vdc

    Power supply, 18~50 VDC, Including voltage fluctuation and EMF voltage.

    U

    Motor phase U

    V

    Motor phase V

    W

    Motor phase W

     